532nm Ultra-Narrow Bandpass Filter for Life Sciences & Fluorescence

OD6+ Deep Blocking | < 3nm FWHM | Unmatched Signal-to-Noise Ratio

Technical Specifications

Technical ParameterSpecification
SubstratePremium Fused Silica / UV Grade Glass
Center Wavelength (CWL)532nm ± 0.5nm
FWHM (Bandwidth)2nm - 3nm (Customizable)
Peak Transmittance> 85% @ 532nm
Out-of-Band Blocking≥ OD6 (T < 0.0001%) @ 200nm - 1200nm
Angle of Incidence (AOI)0° ± 2°
Surface Quality20-10 Scratch and Dig (High Precision)
Clear aperture> 90% of central dimension
Coating TechnologyHard Ion-Assisted Deposition (IAD)

Product Overview

Optimized for Fluorescence & PCR

In life sciences, every photon counts. Our 532nm ultra-narrow filters are the core optical engine for fluorescence microscopy, flow cytometry, and real-time PCR instruments. By completely suppressing excitation light leakage and background autofluorescence, we empower your sensors to detect the faintest emission signals with absolute certainty.

Zero-Shift Dielectric Coating

We don't compromise on coating density. Utilizing advanced IAD technology, we deposit hundreds of ultra-thin layers to create a "solid-state" filter that is impervious to moisture and thermal variations. This means the 532nm center wavelength remains locked in place, ensuring your instruments deliver consistent, repeatable test results year after year.

Compliant B2B Supply & Assembly

Navigating global optics procurement shouldn't be risky. We focus strictly on B2B civilian applications. Free from export-restricted materials like Germanium, our supply chain is transparent and stable. Whether you need bare filters or custom optical sub-assemblies for your next-gen medical devices, we deliver without the red tape.

Metrology & Performance Reports


Figure 1: Ultra-Narrow Transmittance & OD6 Blocking Curve
Target Wavelength: 532nm CWL | Application: Fluorescence Excitation/Emission
The spectrophotometer data reveals a needle-like transmission spike precisely at 532nm, seamlessly transitioning into a flatline of OD6+ blocking across the detector’s sensitive range (up to 1000nm).

Performance Validation & Metrology Analysis

  • Testing Equipment: Ultra-High Resolution UV-VIS-NIR Spectrophotometer.
  • Target Wavelength: 532nm (Optimized for Nd:YAG lasers and green-excited fluorophores).

  • Performance Index: Peak Transmittance > 85% & Out-of-band Blocking ≥ OD6.

  • Optical Edge: The “square-wave” spectral profile guarantees razor-sharp cut-on and cut-off edges, crucial for separating closely spaced fluorophore emission peaks.

  • Benefit: Dramatically lowers the limit of detection (LOD) in your bio-analytical instruments, giving your end-users unprecedented imaging clarity and diagnostic accuracy.

Leverage Our In-House Metrology Capabilities

Designing a new fluorescence detection module? Don’t let mismatched optics bottleneck your sensor’s potential. We transition beyond standard component trading by offering comprehensive technical service. Connect with our engineering team for spectral curve matching, tolerance analysis, and custom optical sub-assembly integration, ensuring your life science instruments perform flawlessly out of the box.